Cummins ISC CM2150 (2007-09) Fault Code: 115 PID: 115 SPN: 115 FMI: 2 Engine Magnetic Speed/Position Lost Both of Two Signals – Data Erratic, Intermittent, or Incorrect. The engine control module (ECM) has detected that the primary and backup speed sensor signals are connected backwards.

Description

Verify the ECM calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM.

This fault code indicates that the camshaft position sensor and crankshaft position sensor wiring harness connectors are reversed.

Possible repairs:

1)If necessary, calibrate the ECM.
2)Replace the ECM.

Reviews

There are no reviews yet.

Be the first to review “Cummins ISC CM2150 (2007-09) Fault Code: 115 PID: 115 SPN: 115 FMI: 2 Engine Magnetic Speed/Position Lost Both of Two Signals – Data Erratic, Intermittent, or Incorrect. The engine control module (ECM) has detected that the primary and backup speed sensor signals are connected backwards.”