Reason:
Injector Solenoid Driver Cylinder 6 – Mechanical System Not Responding or Out of Adjustment. The ECM has detected an error with the injection timing or quantity.
Effect:
Possible reduced engine performance.
Circuit Description:
The ECM uses diagnostic software to verify injector operation. During selected conditions, each injector is fired. The fueling quantity and timing are then compared to a specified threshold.
Component Location:
The engine harness connects the ECM to the pass-through connector(s) that are located in the rocker housing. Internal injector harnesses are located under the valve cover and connect the injectors to the engine harness at the pass-through connector(s).
Conditions for Running the Diagnostics:
This diagnostic runs periodically during engine operation.
Conditions for Setting the Fault Codes:
The Engine Control Module (ECM) detected a fueling timing or quantity error for the specified injector.
Action Taken When the Fault Code is Active:
The ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.
Conditions for Clearing the Fault Code:
It is necessary to use the “Reset All Faults” command in INSITE™ electronic service tool to clear this fault and extinguish the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL).
Shop Talk:
This fault code is intended to identify fueling quantity and timing issues.
Possible Causes:
1) Inactive fault codes
2) Faulty ECM
We’ll never share your email address with a third-party
Reviews
There are no reviews yet.